Acrel ADW210-D16-4S Multi Channel 3 Phase Wireless Energy Meter Iot With External Cts For Base Station
$28.77
$35.67
Acrel ADW210-D16-4S Multi Channel 3 Phase Wireless Energy Meter Iot With External Cts For Base StationADW2XX rail type multi-circuit power meters are mainly used to measure the complete electrical parameters of multiple three-phase circuits. They can be connected to the current input of up to four three-phase circuits simultaneously. It can measure voltage and current, power, power factor, phase angle, unbalance, harmonics and other parameters.Main features:Monitoring: Up to 4 three phase circuits or 12 single phase circuits;Rated voltage: AC 3x220V/380V;Rated current: 5A, 100A, 400A or 600A AC (with external CTs);Communication: RS485 (MODBUS-RTU);LCD Display;Standard and Certificate: CE;Detail InformationType:Multi Circuit Energy MeterCommunication:RS485Installation:DIN Rail InstallationCertificate:CEStandard:IEC62052-11/IEC62053-21Highlight:3 phase wireless energy meter it multi channel wireless energy meter iot wireless energy meter 1. Main model functions: Auxiliary powerAC/DC 85~265V; Consumption≤10VA;InputFrequency45~65Hz;VoltageAC 3×220V/380V; Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1sConsumption: ≤ 0.5VA;CurrentAC 5A,100A,400A,600A;(External opening transformer); Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s;Consumption: ≤ 0.5VAMeasurement AccuracyFrequency 0.05Hz;Voltage,current: 0.5 level;Active electric energy: level 1;Reactive electric energy: level 2;2-31st times harmonic accuracy: ± 1%;FeaturesPulse OutputOutput mode: optocoupler pulse with open collector;CommunicationRS485, Modbus-RTU; Baud rate 1200~38400;SwitchingInputDry contact input,Built-in power supply; OutputOutput mode: Relay normally open contact output; contact rating: AC 250V/3A DC 30V/3A;OutlineL*W*H(mm)72*97.7*71.5EnvironmentWorking temperature-10℃~ 45℃Storage temperature-40℃~ 70℃Relative humidity≤95% No condensationAltitude≤2500m 2. Expanded model functions:Switch modulePower supplyRJ45 interface, DC 12V, power consumption ≤1W;CommunicationRJ45 interface, Modbus-RTU protocol; (communication with the main body)Switch inputDry contact input, built-in power supply;Switch outputOutput mode: normally open contact output relay;Contact capacity: AC 250V/3A DC 30V/3A;Temperature measurement leak modulePower supplyRJ45 interface, DC 12V, power consumption ≤1W;CommunicationRJ45 interface, Modbus-RTU protocol; (communication with the main body)Temperature measurementStandard NTC temperature sensor, measuring range -20~100℃;Leak measurementThe residual current transformer is connected, the measurement range is 10 ~ 3000 mA;Measurement accuracyTemperature ±2℃, leak level 1; Dimensions Front Panel Guide Rail Installation Wiring3P4WOptional modules External Module (MTL)12 External NTC Temp. Measurement4 Channels Residual Current Measurement External Wireless Module(AWT100)Downlink RS485; Uplink 4G, 2G, NB, Lora, LoraWAN, Ethernet, WiFi, GPS, ProfibusExternal Module(MK)12 Channels DI 4 Channels DONetwork SKU: LKOTS00060 Category: Over the See Tag: Pre order
Over The See